Working current |
≤40uA |
---|---|
Maximum Discharge Current |
40 A |
Instantaneous Discharge Current |
70 A |
Charging voltage |
25.5 V |
Temperature range |
-30/+80°C |
BMS (Battery Management System) – a battery management system that is designed to monitor the status of batteries, control the process of charging/discharging the battery, etc.
Six batteries (18650) can be connected simultaneously to this charge-discharge controller module. The module has protection against short circuit, overcharge and over-discharge. One of the functions of the charge controller is to turn off the power supply for the batteries when the maximum capacity of at least one battery is reached. This BMS controller is designed for more than 30,000 hours of operation. The maximum allowable current is 40 A.
If the maximum permissible value of the supply voltage is exceeded, the charge controller activates the “protection” mode. In order to restore the module, it is necessary to re-apply voltage to the input of the BMS board or wait a while until the charge controller automatically disables protection.
Reviews
There are no reviews yet.